Spare Parts

Spare Parts

Part No.
Image
Name and Descriptoin
30699

Stratos-Micra Filter Cartridge

This dust separator cartridge installs in the Stratos-HSSD detector only. The cartidge is not cleanable and must be replaced when contaminated. Stratos-HSSD monitors the separator condition and will generate a separator fault when replacement is necessary.

30072

Stratos-HSSD2 Filter Cartridge

This dust separator cartridge installs in the Stratos-HSSD detector only. The cartidge is not cleanable and must be replaced when contaminated. Stratos-HSSD monitors the separator condition and will generate a separator fault when replacement is necessary.

30431

Input Relay Card

The Input Relay Card can be fitted to any one of the Stratos series detectors. On the Stratos-Micra it provides extra outputs so that relays are available for all four alarm levels including a fault relay. On a Stratos-HSSD 2 it gives a second set of relays that duplicates the standard relays. The fault relay contact is normally closed and the alarm relays are normally open. It also provides three configurable inputs which can be used for Remote Reset, Remote Isolate and ClassiFire Override.

30805

Contact Monitor

The Stratos Contact Monitor enables the integration of other manufacturers equipment into Stratos/SenseNET system networks. Relay outputs from other devices are monitored for alarm levels and fault. Two other general purpose inputs are also available. RS485 communications connects the monitored device to a Stratos Command Module or PC Graphics Station for remote monitoring/alarm purposes.

30802

Remote Display Unit

RDU will mimic the display of a Stratos detector connected to it via the RS485 SenseNET network bus. A bank of switches selects the detector display to be repeated.
The unit consists of a 3 U high metal front panel plate with a graphics overlay and a main PCB which contains terminals for power supply and RS485 highway.

An optional PCB (model 30803) provides volt-free relay contacts to provide alarm switching on alarm conditions of the detector(s).

30817

Single RDU wall mounting enclosure

Rugged sheet metal enclosure for housing RDU card (model 30802) and Remote Display Relay Board (model 30803).

30803

Remote Display Unit relay board

The RDU relay board duplicates the alarm and fault relays of the detector being monitored. An extra relay gives an output when remote input 1 on a detector is triggered.

30804

PC Interface

Use the PC Interface when connecting a PC to the SenseNET bus without a Command Module. The unit comes complete with SenseNET software CD, SenseNET manual and mains and RS232 cables.

30419

9-Pin Null Modem Serial Cable - Female/Female

Required for PC Programming.